Cleanroom Air Supply, Filter Fan Units & Laboratory Ventilation
KrantzHEPA outlets Puri-Drall, Puri-Clean and Puri-Inlet for ISO 6 to 8 and EU GMP C and D cleanrooms, FFU and stainless AHU for pharma and food, LAB-V lab outlets.
HEPA filter air outlets Puri-Drall PDK, Puri-Clean PCK and Puri-Inlet PEK
HEPA filter air outlet with pull-down outlet element, for air cleanliness classes 6 to 8 to DIN EN ISO 14644-1, respectively C and D according to EU GMP.
- Volume flow 250 to 850 m³/h standard housing; 800 to 1,400 m³/h rectangular housing; cross-section 570 × 570 mm or 1,195 × 570 mm
- HEPA filter cell H13 or H14 with aluminium frame; dry sealing (with or without test groove) or fluid sealing; recovery test per DIN EN ISO 14644-3
- Galvanised sheet housing powder-coated RAL 9010; air distribution element RAL 9005
- Applications: pharmaceutical clean room areas, hospitals, laboratories, food industry
Filter fan units FFU and air handling units AHU
FFU and AHU are used in clean rooms to ensure consistently high air purity. FFUs are usually integrated into the ceiling and are used to protect sensitive production processes. Krantz AHUs are customised special solutions, can be equipped with various filter stages, fans, insulation, cooling and heating coils and have significantly higher air volumes than FFUs.
Stabilised stainless steel; space-saving component arrangement; customised filter stage combination
- Fully welded housing from the last HEPA or ULPA stage for food production; splash guard; multi-stage AHU variants; energy-efficient fans, full stainless if required; double-walled insulated housing available
- Applications FFU: semiconductor, microelectronics and wafer clean rooms, pharma, food, laboratories, hospitals and isolation wards; AHU: food industry
- Filling cabin and clean working cabin UltraFlex clean room for the food industry
Laboratory outlet LAB-V
Laboratory outlet with a high volume flow rate to generate a low turbulence room air flow to supply fresh air and protect laboratory personnel, reducing washout effects at fume hoods. Volume flow 700 to 1,700 m³/h; sizes 1,500 and 2,000 mm; maximum cooling load 130 to 190 W/m². Hybrid low-turbulence mixing-displacement ventilation, adaptable to room load. Our demo laboratory room with fume hoods in Aachen is used to analyse laboratory-specific air distribution systems.
Hospitals, isolation wards and high-security laboratories
In the hospital segment, we have expertise and products in the field of nuclear medicine, category 1b operating theatres as well as isolation wards. Being the market leader, we offer suitable filter systems and damper systems for research and high-security laboratories with protection levels BSL3 and BSL4. With more than 25 years of experience in supplying leading laboratories worldwide, we are the right partner for planners, contractors and operators; we have already supplied more than 2,000 customised filter and valve systems as the final barrier to the environment for leading national and international research institutes (see Nuclear-Grade HEPA & Sorption Filter Systems).